{"id":7631,"date":"2026-09-09T15:04:19","date_gmt":"2026-09-09T15:04:19","guid":{"rendered":"https:\/\/gog-elec.com\/?p=7631"},"modified":"2026-09-09T15:04:22","modified_gmt":"2026-09-09T15:04:22","slug":"weatherproof-outdoor-outlet-covers-for-las-vegas","status":"publish","type":"post","link":"https:\/\/gog-elec.com\/es\/blog\/weatherproof-outdoor-outlet-covers-for-las-vegas\/","title":{"rendered":"Cubiertas para Tomas de Corriente Exteriores a Prueba de Intemperie para Las Vegas"},"content":{"rendered":"<p>Una de las condiciones clim\u00e1ticas m\u00e1s severas en los EE. UU. es la que afecta a las tomas externas de Las Vegas, donde las temperaturas m\u00e1ximas de verano alcanzan los 115 grados Fahrenheit, y se pueden contar cientos de rayos solares o tormentas de lluvia que ocurren en una hora o m\u00e1s. Desafortunadamente, las cubiertas ordinarias para tomas cubiertas, o incluso las cubiertas abatibles m\u00e1s anticuadas usadas en exteriores, no pueden soportar tal asalto de la naturaleza. Este art\u00edculo describe c\u00f3mo funcionan las cubiertas para tomas a prueba de clima, por qu\u00e9 es imprescindible utilizar cubiertas extra resistentes en Las Vegas, qui\u00e9n las produce y vende en la ciudad, cu\u00e1les son sus precios y c\u00f3mo elegir, instalar y mantenerlas adecuadamente para que la toma contin\u00fae us\u00e1ndose durante decenas de veranos consecutivos despu\u00e9s de la compra.<\/p>\n<blockquote><p>La versi\u00f3n corta: En las tomas exteriores de Las Vegas, necesitar\u00e1 el tipo a prueba de clima de cubiertas extra resistentes para uso mientras est\u00e1 en uso \u2014 las cubiertas especiales tipo \u201cburbuja\u201d que mantienen sus propiedades protectoras mientras un cable est\u00e1 conectado, seg\u00fan lo establecido en el Art\u00edculo 406.9(B)(1) del NEC que aplica a ubicaciones h\u00famedas. La cubierta debe estar protegida por GFCI y estar fabricada con material resistente a la intemperie (WR). Algunas marcas reconocidas que puede encontrar en una tienda de suministros el\u00e9ctricos en Las Vegas son TayMac, Hubbell\/Bell, Leviton, Arlington, Pass &amp; Seymour\/Legrand.<\/p><\/blockquote>\n<h2>\u00bfQu\u00e9 es una cubierta para toma exterior a prueba de clima?<\/h2>\n<p>Una cubierta para toma a prueba de clima es ese recinto que protege un enchufe externo de la lluvia, nieve, suciedad y rayos UV cuando no est\u00e1 conectado nada y, en el caso de su forma moderna, mientras un cable est\u00e1 fijado a la toma y la cubierta est\u00e1 asegurada. La segunda parte es exactamente lo que exige el c\u00f3digo actual. Las tapas abatibles anteriores solo pod\u00edan proteger la toma cuando no estaba en uso; una vez que conectaba algo importante como luces navide\u00f1as, un temporizador de agua o una bomba de piscina, la tapa ten\u00eda que abrirse, exponiendo as\u00ed la toma.<\/p>\n<p>La respuesta moderna es la cubierta para uso mientras est\u00e1 en uso. Tiene una tapa grande y puede ser de forma esf\u00e9rica o plana en cajas de unidades comerciales, que cuenta con algunas muescas o una capa flexible en la parte inferior que permite conectar el cable mientras la cubierta est\u00e1 bloqueada. Seg\u00fan el C\u00f3digo El\u00e9ctrico Nacional (NEC), toda toma instalada en exteriores se reconoce como una \u201cubicaci\u00f3n h\u00fameda\u201d, y la letra H del NEC 406.9(B) estipula que debe estar protegida por un recinto a prueba de clima, que siga siendo efectivo cuando el cable est\u00e9 conectado. La cubierta en s\u00ed debe ser de \u201cextra resistencia\u201d, lo que significa que pas\u00f3 pruebas especiales que garantizan su resistencia a impactos y fue aprobada por UL para su uso en ubicaciones h\u00famedas. Por lo tanto, aseg\u00farese de revisar la etiqueta del empaque en lugar de simplemente tomar cualquier caja del estante.<\/p>\n<p>Hay dos reglas m\u00e1s relacionadas con la cubierta. El recept\u00e1culo que cubre debe estar protegido por GFCI (el NEC exige que esto sea cierto para todos los enchufes de 15 y 20 amperios y 125 voltios instalados en exteriores) y debe ser repelente al clima (WR) a partir de 2008. La anatom\u00eda del enchufe debajo de la cubierta \u2014 y por qu\u00e9 las versiones WR y resistentes a manipulaciones son importantes en exteriores \u2014 se explica en nuestro <a href=\"https:\/\/gog-elec.com\/es\/blog\/what-is-an-electrical-receptacle\/\">gu\u00eda de recept\u00e1culos el\u00e9ctricos<\/a>.<\/p>\n<h2>Por qu\u00e9 Las Vegas es un caso especial<\/h2>\n<p>Las Vegas (y el \u00e1rea m\u00e1s grande del condado de Clark) tiene tres condiciones ambientales que act\u00faan en combinaci\u00f3n para causar que el equipo el\u00e9ctrico exterior econ\u00f3mico se desgaste mucho m\u00e1s r\u00e1pido all\u00ed que en casi cualquier otra parte del pa\u00eds.<\/p>\n<ul>\n<li><span style=\"color: #ff0000;\">Rayos UV sin precedentes:<\/span> Situada a unos 3,600 pies sobre el nivel del mar y con m\u00e1s de 300 d\u00edas soleados al a\u00f1o, el valle est\u00e1 sujeto a cantidades extremas de luz solar. Las violaciones del pl\u00e1stico estabilizado contra UV causan amarillamiento, agrietamiento y fragilidad en un par de temporadas; los sellos se secan y agrietan. El policarbonato con estabilizadores UV o el aluminio fundido a presi\u00f3n marcan la diferencia entre una cubierta con una vida \u00fatil de una d\u00e9cada y una que se rompe al abrirse.<\/li>\n<li><span style=\"color: #ff0000;\">Calor:<\/span> Temperaturas de tres d\u00edgitos en verano, as\u00ed como el asfalto negro y el concreto alrededor, hacen que las temperaturas superficiales sean mucho m\u00e1s altas que la temperatura real del aire. Los termopl\u00e1sticos baratos se ablandan y deforman mientras que los sellos tambi\u00e9n sufren. Los materiales de las cubiertas para paredes expuestas al sol deben estar especialmente dise\u00f1ados para resistir el calor.<\/li>\n<li><span style=\"color: #ff0000;\">Tormentas monz\u00f3nicas y polvo:<\/span> De julio a septiembre ocurre el monz\u00f3n norteamericano con r\u00e1fagas, lluvias torrenciales y arena transportada por el viento. Despu\u00e9s de las lluvias, el polvo se asienta en las superficies bajo el sol caliente, lo que explica por qu\u00e9 los orificios de drenaje y los sellos limpios son tan importantes aqu\u00ed en comparaci\u00f3n con otros lugares.<\/li>\n<\/ul>\n<p>Luego est\u00e1 el aspecto regulatorio: cada enchufe exterior ubicado en las cercan\u00edas de piscinas y usos de spa debe cumplir con las reglas adecuadas seg\u00fan las leyes del Art\u00edculo 680 del NEC; las inspecciones de nuevas instalaciones y trabajos de renovaci\u00f3n se realizan conforme a la \u00faltima edici\u00f3n adecuada del NEC; las regulaciones del sur de Nevada exigen estrictamente cubiertas para lugares h\u00famedos porque la principal raz\u00f3n para que se active el GFCI es que el agua entre en un enchufe activo, por lo que la regla pr\u00e1ctica para Las Vegas dice: se requieren cubiertas para lugares h\u00famedos y WR\/GFCI en los enchufes exteriores, incluidos los ubicados bajo el techo del patio.<\/p>\n<h2>Los tipos de cubiertas resistentes al clima<\/h2>\n<p>La familiaridad con las tres familias facilita la lectura del estante (o la lista en l\u00ednea):<\/p>\n<table>\n<tbody>\n<tr>\n<th>Tipo<\/th>\n<th>Materiales<\/th>\n<th>Mejor para<\/th>\n<th>Veredicto de Las Vegas<\/th>\n<\/tr>\n<tr>\n<td>Cubierta \u201cburbuja\u201d para uso mientras est\u00e1 en uso, grado residencial<\/td>\n<td>Policarbonato estabilizado contra UV<\/td>\n<td>Enchufes de patio, exterior de garaje, iluminaci\u00f3n navide\u00f1a, en cualquier lugar donde un cable permanezca conectado<\/td>\n<td>Mejor valor para la mayor\u00eda de los hogares; reemplazar si el pl\u00e1stico alguna vez se amarillea o agrieta<\/td>\n<\/tr>\n<tr>\n<td>Cubierta para uso mientras est\u00e1 en uso, extra resistente, met\u00e1lica<\/td>\n<td>Aluminio fundido a presi\u00f3n con recubrimiento en polvo y junta de espuma<\/td>\n<td>Propiedades comerciales, equipo de piscina, \u00e1reas de alto tr\u00e1fico, resistencia a la corrosi\u00f3n grado costero<\/td>\n<td>El est\u00e1ndar comercial; la clasificaci\u00f3n de impacto es realmente \u00fatil cerca de piscinas y patios traseros<\/td>\n<\/tr>\n<tr>\n<td>Cubiertas de cierre autom\u00e1tico \/ abatibles (estilo antiguo)<\/td>\n<td>Metal o pl\u00e1stico, cierre por resorte o gravedad<\/td>\n<td>Solo para ubicaciones h\u00famedas donde ning\u00fan cable permanezca enchufado<\/td>\n<td>Evitar para exposiciones mojadas \u2014 incumple el c\u00f3digo una vez que un cable est\u00e1 en uso<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Tambi\u00e9n existen cajas de montaje superficial (para tomacorrientes que deben sobresalir sobre revestimientos de solapa) y unidades \u201cpop-up\u201d empotradas para aplicaciones en patios y terrazas. Para la mayor\u00eda de las viviendas en Las Vegas, la cubierta impermeable de policarbonato estabilizado contra UV de 1 o 2 m\u00f3dulos es la opci\u00f3n adecuada; para piscinas y spas, y en aplicaciones comerciales, opte por metal resistente o la versi\u00f3n pl\u00e1stica especialmente marcada como \u201cheavy-duty\u201d. El conjunto completo de tipos de tomacorrientes y el contexto del c\u00f3digo alrededor de cada uno est\u00e1 mapeado en nuestro <a href=\"https:\/\/gog-elec.com\/es\/blog\/what-are-the-4-types-of-electrical-outlets\/\">tipos de tomacorrientes el\u00e9ctricos gu\u00eda<\/a>.<\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-7634\" src=\"https:\/\/gog-elec.com\/wp-content\/uploads\/2026\/09\/Which-brands-and-suppliers-serve-Las-Vegas.webp\" alt=\"Which brands and suppliers serve Las Vegas\" width=\"1448\" height=\"1086\" \/><\/p>\n<h2>\u00bfQu\u00e9 marcas y proveedores sirven a Las Vegas?<\/h2>\n<p>En Las Vegas, los proveedores son los mismos puntos de venta nacionales que se encuentran en todo Estados Unidos, disponibles en tiendas de grandes superficies, mayoristas el\u00e9ctricos y proveedores de riego y paisajismo.<\/p>\n<table>\n<tbody>\n<tr>\n<th>Marca<\/th>\n<th>Por qu\u00e9 son conocidos<\/th>\n<th>Precio t\u00edpico<\/th>\n<\/tr>\n<tr>\n<td>TayMac<\/td>\n<td>Las cubiertas residenciales m\u00e1s comunes para uso en servicio en stock (series MM410\/MM420, MX3200 extra-duty); placas de montaje 16 en 1, lentes transparentes<\/td>\n<td>$10-22<\/td>\n<\/tr>\n<tr>\n<td>Hubbell \/ Bell<\/td>\n<td>Cubiertas comerciales e industriales de aluminio fundido a presi\u00f3n extra resistentes (serie PVL100), con cerradura, resistentes al aire salino<\/td>\n<td>$28-45<\/td>\n<\/tr>\n<tr>\n<td>Leviton<\/td>\n<td>Enfoque de sistema completo: recept\u00e1culos WR, dispositivos GFCI\/WR y cubiertas de gama media; serie 5981 heavy-duty<\/td>\n<td>$15-30<\/td>\n<\/tr>\n<tr>\n<td>Arlington<\/td>\n<td>Cajas para revestimientos y soluciones de montaje especializadas que mantienen las cubiertas al ras y drenadas en paredes exteriores<\/td>\n<td>$18-28<\/td>\n<\/tr>\n<tr>\n<td>Pass &amp; Seymour \/ Legrand<\/td>\n<td>Dispositivos WR de grado especificaci\u00f3n y a prueba de manipulaciones con cajas a juego<\/td>\n<td>$12-35<\/td>\n<\/tr>\n<tr>\n<td>GOG y otros fabricantes certificados de dispositivos de cableado<\/td>\n<td>Gamas completas de recept\u00e1culos resistentes a la intemperie, dispositivos GFCI, interruptores y tomacorrientes dise\u00f1ados seg\u00fan normas UL\/IEC, vendidos a trav\u00e9s de distribuidores<\/td>\n<td>Nivel de valor, t\u00edpicamente 20-40% por debajo de las marcas premium estadounidenses con la misma especificaci\u00f3n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u00bfD\u00f3nde compran estos productos los residentes de Las Vegas? En la pr\u00e1ctica: en Home Depot y Lowe\u2019s para compras minoristas de TayMac\/Leviton; en mayoristas el\u00e9ctricos (como Platt, Border States y sucursales relacionadas con CES y mostradores locales que trabajan con electricistas licenciados) para productos Hubbell y Arlington; y por Internet para productos de volumen y especializados. Los contratistas licenciados obtienen materiales al por mayor mientras que la mayor\u00eda de los propietarios compran en tiendas minoristas o en l\u00ednea; sin embargo, ambos tipos de minoristas venden productos listados por UL, y los inspectores de construcci\u00f3n del condado de Clark prestan atenci\u00f3n a esta certificaci\u00f3n.<\/p>\n<p>Por lo tanto, debe notarse que el tomacorriente en s\u00ed es tan importante como la cubierta. Usar una cubierta $15 en un tomacorriente interior no resistente a la intemperie que cuesta $2 violar\u00e1 los c\u00f3digos. Por eso, los dispositivos exteriores resistentes a la intemperie de grado especificaci\u00f3n \u2014 como recept\u00e1culos d\u00faplex WR, combinaciones GFCI\/WR autopruebas y interruptores anticorrosi\u00f3n \u2014 se venden como parte de kits equipados con cubiertas, y la misma l\u00f3gica de certificaci\u00f3n aplica tanto para productos estadounidenses como extranjeros. Para una visi\u00f3n m\u00e1s amplia de c\u00f3mo se comparan las marcas de dispositivos de cableado \u2014 y d\u00f3nde encajan los fabricantes de valor en el mercado \u2014 nuestro <a href=\"https:\/\/gog-elec.com\/es\/blog\/top-10-wiring-devices-brands-in-the-world\/\">ranking de las principales marcas de dispositivos de cableado a nivel mundial<\/a> is a useful read before you buy in bulk.<\/p>\n<p>If you need a complete outdoor wiring device instead of just the covers to do a rewire, a rental property, or a commercial project, the same approach applies to selecting switch and socket manufacturers as it would if looking for cover brands: check their certification, verify their materials, and compare technical specifications.The buyer&#8217;s guide from switch-and-socket manufacturer igotoele on <a href=\"https:\/\/igotoele.com\/blog\/industry-dynamics\/how-to-choose-electric-switch-socket-manufacturer\/\" target=\"_blank\" rel=\"noopener\">how to choose an electric switch and socket manufacturer<\/a> walks through exactly those checks, and it applies to outdoor devices as much as indoor ones.<\/p>\n<h2>What do outdoor outlet covers cost in Las Vegas?<\/h2>\n<p>Pricing in the Las Vegas market mimics national figures for retail while wholesale prices to contractors are lower:<\/p>\n<table>\n<tbody>\n<tr>\n<th>Producto<\/th>\n<th>Retail price (typical)<\/th>\n<th>Notes<\/th>\n<\/tr>\n<tr>\n<td>Polycarbonate while-in-use cover, 1-gang (TayMac MM410\/MM420 class)<\/td>\n<td>$10-18<\/td>\n<td>Residential default; buy the clear-lens, 16-in-1 mount version for easiest fit<\/td>\n<\/tr>\n<tr>\n<td>Extra-duty while-in-use cover, metal (Hubbell Bell PVL class)<\/td>\n<td>$28-45<\/td>\n<td>Commercial\/pool work; lockable options<\/td>\n<\/tr>\n<tr>\n<td>WR duplex receptacle behind the cover<\/td>\n<td>$6-20<\/td>\n<td>Leviton 5262-W class at ~$8-10; spec-grade higher<\/td>\n<\/tr>\n<tr>\n<td>Self-test GFCI\/WR receptacle<\/td>\n<td>$17-30<\/td>\n<td>Required on outdoor circuits; test monthly<\/td>\n<\/tr>\n<tr>\n<td>2-gang or 3-gang covers, metal extra-duty<\/td>\n<td>$35-70<\/td>\n<td>Multiple outlets or switch+outlet combos<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The economics make the case for doing the job the right way \u2014 a cover costing somewhere in the range of $10-15 that is complemented with a WR\/GFCI receptacle at a cost of $20-30 will ensure against the presence of water that can cause circuit trips, corrosion, and possibly fires or an electrical shock. The cost of buying the components is practically negligible in comparison to the expenses incurred with a service call. Buying covers for all the external outlets at once (owner can save significantly by making the purchase in packs of three) constitutes the cheapest form of insurance that homeowners can get in Las Vegas.<\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-7635\" src=\"https:\/\/gog-elec.com\/wp-content\/uploads\/2026\/09\/How-to-choose-the-right-cover-and-brand.webp\" alt=\"How to choose the right cover and brand\" width=\"1448\" height=\"1086\" \/><\/p>\n<h2>How to choose the right cover and brand<\/h2>\n<p>Ensure you follow these steps to be successful in this weather.<\/p>\n<ul>\n<li>Review wet location requirements. If there is an outdoor outlet that can get rained on while being plugged in, an extra-duty while-in-use cover with UL wet-location listing and GFCI-protected circuit must be used. There is no way around this rule since it has to do with Clark County inspections and the laws of physics.<\/li>\n<li>Make sure that the materials match exposure conditions. If it\u2019s full sun exposure, choose UV-stabilized polycarbonate or die-cast aluminum; bare cheap plastic should not be used. For pools and commercial places, only extra-duty metal and impact-rated plastic should be considered. Coastal-grade protection against corrosion is overkill in the desert, but aluminum units can withstand children, hail, and pool equipment as well.<\/li>\n<li>Check the mounting plate orientation. Most covers are 16-in-1, so they will fit standard Decora and duplex outlet, but some are horizontal or vertical; measure your box and outlet type. The cover must completely shut over the plugs being used. If using bulky transformer plugs, make sure bubbles are deep enough.<\/li>\n<li>Check the device behind the cover. If the current receptacle is old, rated for indoor use only, or there is no GFCI protection, replace it while the cover is off, as there is very little difference in cost, and the effect of inspection is real. The selection logic for choosing any wiring device \u2014 certification, ratings, and brand credibility \u2014 is laid out in our <a href=\"https:\/\/gog-elec.com\/es\/blog\/how-do-you-select-wiring-devices\/\">c\u00f3mo seleccionar dispositivos de cableado<\/a> gu\u00eda.<\/li>\n<li>Purchase from a reliable source. Use a big box retailer for a single cover, access wholesalers for contractor volume, and authorized online distributors for special sizing. Check for UL mark on the box as there is an issue with counterfeits and unlisted \u201cweatherproof\u201d covers available online, and unlisted cover is guaranteed to fail at the worst time possible when there is a monsoon.<\/li>\n<\/ul>\n<h2>Installation and maintenance notes for desert homes<\/h2>\n<p>Cover installation takes less than ten minutes, but three things distinguish a dry outlet from a wet one once the job is done:<\/p>\n<ul>\n<li><span style=\"color: #ff0000;\">Seal only the top and the sides, never the bottom.<\/span> The National Electrical Code requires wet location enclosures to be draining condensation, so once you\u2019ve completed the work on the outlet, run a bead of 100% silicone along the top and side edges of the gasket up against the wall and leave the bottom edge open or clean weep holes out. Sealing all four edges prevents water from draining and causes corrosion.<\/li>\n<li><span style=\"color: #ff0000;\">Match the gasket to the base material.<\/span> If you are working with stucco or uneven block (the common exterior in Las Vegas), cover the back of the gasket with sealant, so the cover attaches tightly; if the surface is smooth, usually, factory gasket is already sufficient.<\/li>\n<li><span style=\"color: #ff0000;\">Position the cords expressing down.<\/span> Bring the cords out through the bottom notch, allowing the water to slide down the cord and fall away instead of getting into the plug. This is what the bottom position of the cord notches is for, so please respect the design.<\/li>\n<\/ul>\n<p>Maintenance is performed twice per year, including opening any cover, inspecting the gasket for cracks, and clearing the weep holes; remember about tightening the screws again (the wind in the desert will make them loose over time) and pushing the GFCI button on the receptacle behind.Cracked or yellowed polycarbonate, a gasket that no longer seals, or a hinge that has lost its spring means replacement \u2014 the same moisture-entry failures that show up as the classic outdoor-outlet problems are catalogued in our <a href=\"https:\/\/gog-elec.com\/es\/blog\/the-most-common-problems-in-electrical-switches-are\/\">common switch and socket problems<\/a> gu\u00eda.<\/p>\n<h2>Preguntas frecuentes<\/h2>\n<h3>What is the best weatherproof outdoor electrical outlet cover?<\/h3>\n<p>The TayMac (MM410\/MM420 models) UV-stabilized polycarbonate while-in-use cover is the best option for most home owners because it complies with the NEC extra-duty wet-location standard, maintains its weatherproof characteristics during use, and can withstand years of exposure to sunlight. For more extreme situations like pools, spas, and commercial applications, invest in extra-duty die-cast aluminum covers from Hubbell\/Bell.<\/p>\n<h3>What is the best cover for an outdoor outlet?<\/h3>\n<p>The top outdoor outlet cover for a Las Vegas outdoor outlet is the extra-duty while-in-use cover made of UV-stabilized polycarbonate or a die-cast aluminum cover which is UL-listed for wet locations and which is used in conjunction with a weather-resistant receptacle on a GFCI-protected circuit. Note that the cover is only one half of the solution since the WR\/GFCI device behind it provides the electricity safeguard while the cover offers protection from the weather.<\/p>\n<h3>What is the best weatherproof cover for an outdoor plug?<\/h3>\n<p>If any cords will remain connected, including sky-high power ones (holiday decorations, irrigation devices, pool pumps, charging stations), then you will require a while-in-use cover with an entrance hole in the bottom. The TayMac units provide wonderful solutions for plugs with transformers while the Hubbell metal extra-duty ones are the benchmark for all commercial solutions. It is critical that the cover close entirely over the plug while still being weatherproof in the closed state.<\/p>\n<h3>How can I protect my outdoor electrical outlet from rain?<\/h3>\n<p>In order to make a weatherproof cover effective, one requires an extra-duty while-in-use cover, a circuit protected by GFCI, and a WR receptacle behind it. The upper and sides of the gasket must be sealed, while the bottom needs to remain hinge-free in order for condensation to drain. It is also necessary to install drainage holes in both the upper areas of the cover and the outer edge of the cord, plus GFCI testing must be completed on a monthly basis.<\/p>\n<h2>Referencias<\/h2>\n<ul>\n<li><a href=\"https:\/\/www.nfpa.org\/\" rel=\"nofollow noopener\" target=\"_blank\">NFPA \u2014 National Electrical Code (NFPA 70), Article 406<\/a><\/li>\n<li><a href=\"https:\/\/www.taymac.com\/\" rel=\"nofollow noopener\" target=\"_blank\">TayMac \u2014 Weatherproof Cover Product Lines<\/a><\/li>\n<li><a href=\"https:\/\/www.hubbell.com\/\" rel=\"nofollow noopener\" target=\"_blank\">Hubbell \u2014 Bell Weatherproof Boxes and Covers<\/a><\/li>\n<li><a href=\"https:\/\/www.leviton.com\/\" rel=\"nofollow noopener\" target=\"_blank\">Leviton \u2014 Weather-Resistant and GFCI Devices<\/a><\/li>\n<\/ul>\n<h2>Conclusi\u00f3n<\/h2>\n<p>Outdoor outlets in Las Vegas are bound to see every trick Mother Nature has up her sleeve. Thanks to 115-degree heat and a high concentration of UV rays along with sporadic torrential rains that take the cover off any outdoor equipment, some basic rules apply based on electrical code dictated by Clark County enforceable by inspectors \u2013 each outlet must have an extra-duty while-in-use cover, along with cord-connected devices under GFCI protection. Thus, answers in choosing the hardware used are straightforward with the right rules: TayMac or Leviton UV-stabilized polycarbonate while-in-use covers for nearly every application, priced at $10-20; die-cast aluminum models made by Hubbell\/Bell for industrial tasks at $28-45; and WR\/GFCI devices at any point made by manufacturers such as GOG, which provides high standard quality at low prices. The bottom part must be open for drainage, wires must appear at the lower part, and the GFCI mechanism must be tested regularly.<\/p>","protected":false},"excerpt":{"rendered":"<p>One of the harshest weather conditions in the U.S. is the one that pertains to the external outlets of Las Vegas, where the summer maximum temperatures reach 115 degrees Fahrenheit, and one can count hundreds of sunrays or rainstorms occurring within an hour or longer. Unfortunately, ordinary covered outlet covers, or even more old-fashioned flipping [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":7633,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-7631","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blogs"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/gog-elec.com\/es\/wp-json\/wp\/v2\/posts\/7631","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/gog-elec.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/gog-elec.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/gog-elec.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/gog-elec.com\/es\/wp-json\/wp\/v2\/comments?post=7631"}],"version-history":[{"count":4,"href":"https:\/\/gog-elec.com\/es\/wp-json\/wp\/v2\/posts\/7631\/revisions"}],"predecessor-version":[{"id":7638,"href":"https:\/\/gog-elec.com\/es\/wp-json\/wp\/v2\/posts\/7631\/revisions\/7638"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/gog-elec.com\/es\/wp-json\/wp\/v2\/media\/7633"}],"wp:attachment":[{"href":"https:\/\/gog-elec.com\/es\/wp-json\/wp\/v2\/media?parent=7631"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/gog-elec.com\/es\/wp-json\/wp\/v2\/categories?post=7631"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/gog-elec.com\/es\/wp-json\/wp\/v2\/tags?post=7631"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}