{"id":8429,"date":"2026-11-26T20:20:23","date_gmt":"2026-11-26T20:20:23","guid":{"rendered":"https:\/\/gog-elec.com\/?p=8429"},"modified":"2026-11-26T20:20:26","modified_gmt":"2026-11-26T20:20:26","slug":"understand-the-fundamentals-of-switch-poles-and-throws","status":"publish","type":"post","link":"https:\/\/gog-elec.com\/es\/blog\/understand-the-fundamentals-of-switch-poles-and-throws\/","title":{"rendered":"Understand the Fundamentals of Switch Poles and Throws"},"content":{"rendered":"<p>Every switch is described by two numbers: how many separate circuits it switches at once, and how many positions each of those circuits can reach. Those two numbers are the pole count and the throw count, and almost every switch name is built from them.<\/p>\n<p>A \u201cthrow\u201d refers to the position of the pole when the switch is in the closed position. A standard single-throw switch connects the pole to one contact when the switch is closed and nothing when the switch is opened. <span style=\"color: #c00000;\">A double-throw switch connects the respective pole to either of the two available contacts, which makes it a changeover device rather than an on-off type of switch.<\/span><\/p>\n<blockquote><p><strong>Respuesta r\u00e1pida:<\/strong> a pole is one independent circuit through the switch, and a throw is one position that circuit can connect to. SPST has one pole and one throw, two terminals; SPDT has one pole and two throws, three terminals; DPST has two poles and one throw, four terminals; and DPDT has two poles and two throws, six terminals.<\/p><\/blockquote>\n<h2>What a Pole Is, and What a Throw Is<\/h2>\n<p>Naming conventions are used based on the multiplication of the poles with the last two terms representing the throws. The overall listing would be as follows:<\/p>\n<ul>\n<li>SPST =&gt; Single Pole, Single Throw<\/li>\n<li>SPDT =&gt; Single Pole, Double Throw<\/li>\n<li>DPST =&gt; Double Pole, Single Throw<\/li>\n<li>DPDT =&gt; Double Pole, Double Throw<\/li>\n<li>3PDT =&gt; Three Pole, Double Throw<\/li>\n<li>4PDT =&gt; Four Pole, Double Throw<\/li>\n<\/ul>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-8431\" src=\"https:\/\/gog-elec.com\/wp-content\/uploads\/2026\/11\/Common-Switch-Configurations.webp\" alt=\"Common Switch Configurations\" width=\"1448\" height=\"1086\" \/><\/p>\n<h2>The Common Configurations, by Terminal Count<\/h2>\n<p>Here is a table that displays the electrical switch common configurations based on terminal count:<\/p>\n<table>\n<thead>\n<tr>\n<th>Tipo<\/th>\n<th>Poles<\/th>\n<th>Throws<\/th>\n<th>Terminales<\/th>\n<th>Qu\u00e9 hace<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>SPST<\/td>\n<td>1<\/td>\n<td>1<\/td>\n<td>2<\/td>\n<td>On and off for one circuit<\/td>\n<\/tr>\n<tr>\n<td>SPDT<\/td>\n<td>1<\/td>\n<td>2<\/td>\n<td>3<\/td>\n<td>Changeover, one circuit to either of two<\/td>\n<\/tr>\n<tr>\n<td>SPST<\/td>\n<td>2<\/td>\n<td>1<\/td>\n<td>4<\/td>\n<td>On and off for two circuits together<\/td>\n<\/tr>\n<tr>\n<td>DPDT<\/td>\n<td>2<\/td>\n<td>2<\/td>\n<td>6<\/td>\n<td>Changeover for two circuits together<\/td>\n<\/tr>\n<tr>\n<td>3PDT<\/td>\n<td>3<\/td>\n<td>2<\/td>\n<td>9<\/td>\n<td>Three-phase changeover<\/td>\n<\/tr>\n<tr>\n<td>Intermedio<\/td>\n<td>2<\/td>\n<td>2 (crossed)<\/td>\n<td>4<\/td>\n<td>Middle point in a three-point lighting circuit<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The best way to quickly verify the type of switch in the field is to count the number of terminals on the switch and follow the logical process outlined above: count how many terminals were counted and divide the number by two. For example, a switch with two terminals would be classified as SPST, three would be SPDT, and four could either be classified as a DPST or a type of <a href=\"https:\/\/gog-elec.com\/es\/blog\/what-are-the-four-types-of-light-switches\/\">intermediate switch<\/a>, or if six terminals were counted it could only be classified as DPDT. This method takes ten seconds and eliminates most discussion or confusion regarding the classification of an electrical switch.<\/p>\n<p>The intermediate switch is of note because it resembles a DPST but performs a different function. It features two positions and four terminals, it is what allows the device to connect to a set of <a href=\"https:\/\/gog-elec.com\/es\/product\/ef-002-eu-standard-two-way-switch-1-gang\/\">interruptor de dos v\u00edas<\/a>es to provide another location from which to control the same light.<\/p>\n<h2>British and American Terms for the Same Devices<\/h2>\n<p>A switch that is referred to in the British version as a \u201c2 pole 2 way\u201d would actually be classified as a DPDT in the above nomenclature. Similarly, a switch referred to in the British method as a \u201c1 gang 2 way\u201d would be classified as an SPDT.<\/p>\n<table>\n<thead>\n<tr>\n<th>British term<\/th>\n<th>American equivalent<\/th>\n<th>Terminales<\/th>\n<th>D\u00f3nde se usa<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>One-way switch<\/td>\n<td>Single pole single throw (SPST)<\/td>\n<td>2<\/td>\n<td>Ordinary light switch<\/td>\n<\/tr>\n<tr>\n<td>Interruptor de dos v\u00edas<\/td>\n<td>Single pole double throw (SPDT)<\/td>\n<td>3<\/td>\n<td>Stairs, hallway, two control points<\/td>\n<\/tr>\n<tr>\n<td>Interruptor intermedio<\/td>\n<td>Four-way switch<\/td>\n<td>4<\/td>\n<td>Third control point in a lighting circuit<\/td>\n<\/tr>\n<tr>\n<td>Double pole switch<\/td>\n<td>Double pole single throw (DPST)<\/td>\n<td>4<\/td>\n<td>Cooker isolator, main isolator<\/td>\n<\/tr>\n<tr>\n<td>Two gang<\/td>\n<td>Two single-pole switches on one yoke<\/td>\n<td>4<\/td>\n<td>Two lights on one plate<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"color: #c00000;\">The last two rows of that table are the \u2018trap\u2019. The two switches have four terminals but they cannot be interchanged with each other.<\/span> The first of the two will break two wires of the same circuit at the same time. The second will give you control of two separate switches attached to the same plate, and each switch operates independently of the other.<\/p>\n<p>A cooker isolator appears to be like a single switch, but it is a double pole isolator because both live and neutral wires must be disconnected from the supply so that the appliance is not only isolated but it cannot be switched back on again until the isolator switch has been turned back on.<\/p>\n<h2>What Each Terminal on a Light Switch Does<\/h2>\n<p>The markings found on your British light switch feature conventions which you should be aware of prior to connecting any wires to it.<\/p>\n<p>COM, or L, is the <a href=\"https:\/\/gog-elec.com\/es\/blog\/what-does-common-mean-on-a-light-switch\/\">common terminal<\/a>, providing a path to the power source. In the case of a one-way switch this is defined by the input connection terminal.<\/p>\n<p>An electrical circuit with a two-way switch can have two terminals connected to an outgoing line. The terminals connecting the switch to power are referred to as L1 and L2; they\u2019re the traveller terminals. Each two way circuit, then, connects to the L1 and L2 terminals of the other switch, with one traveller for each outgoing wire; there is no specific way to indicate which wire goes to which terminal, therefore it is possible for the circuit to function regardless of which traveller is connected to which terminal, provided that the connections remain the same. L1-L4 are the travellers on an intermediate switch, and as a result, the L1-4 terminals serve as pairs of switches rather than four independent terminals due to the cross connections of those travellers. The same numbering is used to describe some European two-way switches; therefore, to correctly identify a terminal, a terminal list is more reliable than a label.<\/p>\n<p>There is a three-way switch wiring diagram that details how this three-way switch diagram connects L1 and L2 travellers for a two point circuit. A terminal list does not provide all of this information, whereas a wiring diagram shows what is occurring at both ends of the circuit.<\/p>\n<h2>The Ratings That Matter More Than the Pole Count<\/h2>\n<p>When determining whether a switch can be used, you cannot look solely at the pole count. There are four ratings necessary in order to determine if a switch is suitable; while the pole count helps to determine what a switch can supply, it is not a complete description of a switch\u2019s capabilities.<\/p>\n<p>Current and voltage ratings; AC and DC ratings are supplied separately. A switch rated 10 Amps (A) at 250 Volts (V) alternating current (AC) is not the same as a 10 A switch at 24 V direct current (DC). This difference exists because a DC arc does not automatically extinguish at zero volts. As a result, the ratings for DC load applications are often one-quarter to one-half the rated current rating (A) for an AC application when comparing the same contact set.<\/p>\n<p>Load Type \u2013 There are differences between resistive and inductive loads. The current rating of a resistive load could be rated at 10 A, while an inductive load (motor) could be rated at 4 A. This difference is based on inrush current and arc energy when breaking the circuit.<\/p>\n<p>Contact Material\u2014 The contact material used for the switch is a function of the load. Silver alloys are typically used for general-purpose switches; silver alloys with a hard face are used for inductive loads and frequent operation; and gold is used for dry circuits, where contact resistance is of greater concern than current-carrying capacity.<\/p>\n<p>Terminal Capacity\u2014 Terminal capacity is expressed in square millimetres of wire or American Wire Gauge (AWG). For instance, a switch rated at 45 A with terminals that accept a maximum wire size of <strong>6 mm\u00b2<\/strong> is not equivalent to one rated at 45 A with terminals that accept a maximum wire size of <strong>16 mm\u00b2<\/strong>. The ranges of <a href=\"https:\/\/gog-elec.com\/es\/products\/\">plates, modules, and switches<\/a> are organised according to terminal capacity and not by their appearance. Therefore, two switches that look the same can have different terminal capacities.<\/p>\n<h2>Where Each Configuration Is Used<\/h2>\n<p>Four configurations represent most residential and some light commercial installations, and all four have a specific application.<\/p>\n<ul>\n<li>SPST is the common light switch and the common appliance switch. The SPST switch is used for a single circuit (on-off) and has two terminal connections.<\/li>\n<li>SPDT is the two-way switch used for controlling light fixtures from multiple locations and changing from one source of power to another in smaller-scale transfer switches. If two control points are operated by one light, there are two SPDT switches with the travellers running between the two switches.<\/li>\n<li>DPST is the breaker; these are the cooker control units, the isolators for showers, and the main switches. They break both live and neutral wires, which is the meaning of \u201cisolate\u201d in a home system.<\/li>\n<li>DPDT will changeover two circuits simultaneously. Examples are reversing the direction of a DC motor, switching a circuit between two power supplies, or cross-connecting two sets of traveller wires in a more complex lighting scheme.<\/li>\n<\/ul>\n<p>The link below to \u201cBest Switch on Socket Options for Your Home\u201d will show you a variety of different switch\/socket combinations. The plates will contain DPST isolation switches and 13 A sockets in one unit, and the number of poles on the isolator makes this arrangement legal.<\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-8432\" src=\"https:\/\/gog-elec.com\/wp-content\/uploads\/2026\/11\/Where-Each-Configuration-Is-Used.webp\" alt=\"Where Each Configuration Is Used\" width=\"1448\" height=\"1086\" \/><\/p>\n<h2>C\u00f3mo elegir el adecuado<\/h2>\n<p>To help determine the appropriate choice, there are five questions to consider when selecting a switch\/socket combination:<\/p>\n<ul>\n<li>How many conductors need to be switched? One for a single-pole, two for a double-pole. The appliance needs both hot and neutral wires to be disconnected, which classifies it as a double pole.<\/li>\n<li>Does the circuit require more than one control point? If so, the switches are SPDT, and the number of control points will dictate the number of travellers required and whether an intermediate is necessary.<\/li>\n<li>What is the amperage of the load and is it AC or DC? A DC load with the same current requirement will require a switch rated for DC, as opposed to using a derated AC switch.<\/li>\n<li>What terminal capacity does the cable require? A 45 A switch with a terminal size of 6 mm\u00b2 will not accept a conductor with a cross-sectional area\/allowable current rating greater than or equal to 16 mm\u00b2 unless the circuit to which it connects has been appropriately sized based solely on its design requirements rather than those of the switch itself.<\/li>\n<li>You will also find that different plate formats are available \u2014 i.e. Grid or Modular. The Grid format permits you to change the function of your pole count by adding or removing plates without changing the original layout of your installation. This is important when preparing a project, as you cannot select your accessories until after your layout has been established. For this reason, we have organised our entire range of electrical sockets and electrical switches into plate formats.<\/li>\n<\/ul>\n<h2>Switch Action: Maintained, Momentary and Trip-Free<\/h2>\n<p>\u201cPoles\u201d (the current carrying part of the contact) and \u201cthrows\u201d (the distance that the contact must travel to make contact) are terms that describe the type of contact in any given switch. In addition, there are three additional terms that describe how the actuator will impact the operation of a switch when the actuator is being held, and whether or not the circuit exists while being actuated.<\/p>\n<p><strong>Maintained.<\/strong> This describes your standard light switch. When the light switch is actuated (on\/off), it stays in the position in which it was last actuated. The light switch is always in the last actuation position until it is next actuated. Almost every domestic electrical switch is maintained in this fashion.<\/p>\n<p><strong>Momentary.<\/strong> Momentary switches return to the neutral position when released from their actuation position, and typically, momentary switches will hold the circuit in existence only while the actuator button is being held down. Momentary switches are typically single throw devices, as the switch only creates an electrical circuit while being actuated.<\/p>\n<p><strong>Trip-free.<\/strong> A trip-free switch operates in a manner that protects an electrically faulty circuit by preventing the actuation of the switch from being maintained by a person who continues to apply pressure to the actuator to keep it in the \u201con\u201d position while there is an electrical fault present in the circuit. If the contacts open on their own while the actuator is being actuated (held), the mechanism to trip free will latch open until the actuator has been returned to its neutral position, thereby preventing any electrical faults from being made to operate the switch. Taping the Circuit Breaker\u2019s handle can Disable the Circuit Breaker, but Not the Light Switch; therefore, the Light Switch must be Installed on a Separate Plate or in a Separate Gang.<\/p>\n<p>The number of poles in the Switch does not determine if it is a Double or Single Pole Circuit Breaker; therefore, there are Double Pole Momentary Switches, as well as Single Pole Trip-Free Devices. Please note that specifications should indicate in detail whether the Contact and Actuator are to be counted separately or as One (the part number often indicates this).<\/p>\n<h2>Where the Terminology Goes Wrong<\/h2>\n<p>There are four errors that occur frequently enough in specifications to warrant mention.<\/p>\n<p>Double pole and dual gang. A double-gang plate has the contacts and the actuator in one unit, as two independent single-pole devices. If the two are confused, the plate will not perform as the drawing depicts.<\/p>\n<p>Two-way and <a href=\"https:\/\/gog-elec.com\/es\/blog\/what-is-1-gang-2-gang-and-3-gang\/\">two gang<\/a>. Two-way is a circuit function; two gang is a plate layout. If you wire a two-gang plate of one-way switches correctly, it cannot operate as a two-way circuit.<\/p>\n<p>Four way. A four-way switch is the common American designation for the intermediate switch, with three control points on four terminals. British terminology does not include four-way designs, so a reader may assume it means four gangs. The terminal count settles it.<\/p>\n<p>AC rating covering DC is the most hazardous of the four types of switches; it will work in testing but fail at the first load break. A DC circuit requires a switch with a DC rating.<\/p>\n<p>Three of the four errors originated from a specification written without a terminal count. That is why the comparison of UK switches and plugs lists by terminal count rather than name.<\/p>\n<h2>Preguntas frecuentes<\/h2>\n<h3>What does L1, L2, L3 and L4 mean on a light switch?<\/h3>\n<p>For a Two-way Switch: L1 &amp; L2 are the two \u201ctravelers\u201d and the common is identified as COM (or \u201cL\u201d). The Intermediate (or) Three-way switch: L1 through L4 are two sets of \u201ctraveling wires\u201d that the switch \u201ccross-connects\u201d, allowing it to sit between Two-Way Switches. Counting the terminations (of the switch) is more accurate than reading the markings of the wire, because of the differences in marking conventions and wire colors of manufacturers worldwide.<\/p>\n<h3>What are the three types of switches?<\/h3>\n<p>Three types. By Function: \u201cSingle Pole, Single Throw\u201d for on\/off; \u201cSingle Pole, Double Throw\u201d for changeover between two circuits; \u201cDouble Pole\u201d to break two conductors together. In British language, the same devices (single pole isolator, double pole isolator and intermediate isolator) are classified as one way, two way and intermediate respectively, along with the double pole isolator being the fourth most common household type.<\/p>\n<h3>What does 2 pole single throw mean?<\/h3>\n<p>Two independent circuits operate as one and are switched together. Each of these circuits has one closed position. A two pole single throw switch consists of four terminals, two of which are input and two output. By moving a single actuator, both circuits can be opened. This arrangement is standard for cookers or main switches where live and neutral must be cut off at the same time.<\/p>\n<h3>What is DPDT vs SPDT?<\/h3>\n<p>SPDT switches have one pole and two throws (three terminals) that switch one circuit in two different directions. DPDT switches have two poles and two throws (six terminals) that switch two circuits at the same time between two different directions. A motor reversing switch or a double-supply changeover switch needs a DPDT switch since both lines must change polarity at the same time.<\/p>\n<h2>Referencias<\/h2>\n<ul>\n<li><a href=\"https:\/\/www.electrical4u.com\/\" rel=\"nofollow noopener\" target=\"_blank\">Electrical4U \u2014 Switch Types, Poles and Throws<\/a><\/li>\n<li><a href=\"https:\/\/learn.sparkfun.com\/tutorials\/button-and-switch-basics\/poles-and-throws-open-and-closed\" rel=\"nofollow noopener\" target=\"_blank\">SparkFun \u2014 Button and Switch Basics: Poles and Throws<\/a><\/li>\n<li><a href=\"https:\/\/www.circuitbread.com\/\" rel=\"nofollow noopener\" target=\"_blank\">CircuitBread \u2014 Switches, Contacts and Circuit Functions<\/a><\/li>\n<li><a href=\"https:\/\/www.mk-electric.co.uk\/\" rel=\"nofollow noopener\" target=\"_blank\">MK Electric \u2014 Wiring Accessories and Switch Configurations<\/a><\/li>\n<li><a href=\"https:\/\/www.beama.org.uk\/\" rel=\"nofollow noopener\" target=\"_blank\">BEAMA \u2014 Wiring Accessory Standards and Guidance<\/a><\/li>\n<\/ul>\n<h2>Conclusi\u00f3n<\/h2>\n<p>Poles count the circuits the switch breaks while throws count the positions those circuits can occupy. The number of terminals indicates the number of circuits: two terminals = SPST, three terminals = SPDT, four terminals = DPST or intermediate, and six terminals = DPDT. The names used in British English apply to the same devices, but confusion regarding the terminology has caused most specifications to be incorrect.<\/p>\n<p><span style=\"color: #c00000;\">Poles and gangs are practical distinctions to make.<\/span> A double pole switch opens two conductors with one action, which is necessary for appropriate isolation. A two gang switch consists of two switches on one faceplate, and no amount of wiring can make one a good isolator. It is essential to identify the switch type accurately, and confirm the rating prior to installation because it is the rating (or circuit type) that determines whether the switch will endure its first application of power.<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>Every switch is described by two numbers: how many separate circuits it switches at once, and how many positions each of those circuits can reach. Those two numbers are the pole count and the throw count, and almost every switch name is built from them. A &#8220;throw&#8221; refers to the position of the pole when [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":8430,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-8429","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blogs"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/gog-elec.com\/es\/wp-json\/wp\/v2\/posts\/8429","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/gog-elec.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/gog-elec.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/gog-elec.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/gog-elec.com\/es\/wp-json\/wp\/v2\/comments?post=8429"}],"version-history":[{"count":1,"href":"https:\/\/gog-elec.com\/es\/wp-json\/wp\/v2\/posts\/8429\/revisions"}],"predecessor-version":[{"id":8433,"href":"https:\/\/gog-elec.com\/es\/wp-json\/wp\/v2\/posts\/8429\/revisions\/8433"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/gog-elec.com\/es\/wp-json\/wp\/v2\/media\/8430"}],"wp:attachment":[{"href":"https:\/\/gog-elec.com\/es\/wp-json\/wp\/v2\/media?parent=8429"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/gog-elec.com\/es\/wp-json\/wp\/v2\/categories?post=8429"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/gog-elec.com\/es\/wp-json\/wp\/v2\/tags?post=8429"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}