Cooker Switch With Socket

Cooker Switch With Socket

A cooker switch with a socket is a 45 A double-pole isolator and 13 A outlet provided in a single plate. It is the most popular accessory found in UK kitchens, but it is often purchased for the wrong reasons, as the outlet is simply a convenience and does not need to be provided, and the rating should be specified by the device being connected to it (appliance), not the cooker switch plate.

Réponse rapide : cooker control units consist of double-pole switches rated for up to 45 amps (A) and should be located within 2 metres (m) of the appliance (cooker) but not directly above the cooker hob. They are available with an outlet (13 amp) socket incorporated together with the cooker switch. Although these outlets are convenient, they should not be installed directly above a cooker hob, and some guidelines prohibit them when a gas cooker is being used. A dedicated radial circuit with 6 mm² cable connected to a 32 A or 40 A circuit breaker and sized according to the diversity calculation in BS 7671 Appendix 15, rather than the nameplate rating of your appliance, is recommended. Prices vary by supplier and range from approximately £10 to £25 for a 45 A white wall-mounted cooker switch outlet combination to between £25 and £60 for models made with brushed steel or chrome and priced higher for some brand-name and modular-style systems.

Cooker Switch With Socket

What the Product Is, and What It Is Not

The two main factors that determine whether the item you buy is suitable for you and your installation will be the rating of your cooker switch and how it matches your existing circuit and the appliance connected to it. The second consideration factors in to the position of the unit. A unit that cannot be reached without leaning across a hot hob has no way for you to easily disconnect the unit when you’re working with food. As a result, the appliance will be left in the on position.

The product is defined as a double pole switch, meaning it disconnects both the live and the neutral wire from the mains supply (at the appliance). This is why a double pole switch exists as a device. If you use a single pole switch, it still leaves the neutral wire connected to mains and, as a result, if there is a fault with the appliance, there may still be a risk of electric shock, even when the switch is in the off position.

The cooker unit itself does not work as a circuit breaker and does not provide any form of over current protection. The consumer unit consists of fuses and/or circuit breakers; therefore, cooker units isolate the appliance for maintenance and can also turn off the appliance in case of an emergency; the cooker unit only protects the plug socket version through an internal 13 A fuse.

Cooker units do not replace or fill the role of a cooker connection unit. The common arrangement involves a cooker control unit on the wall at a height of the work surface and a separate cooker connection unit located behind or to the side of the cooker, where the cable tail of the appliance terminates; cooker units with a flexible-cable outlet will have advantages of combining both units and therefore not take up space in the form of a back box; however, they do place the outlet on the wall surface.

45 A or 32 A: Sizing From the Appliance, Not From Habit

Appliances are sized by their recommended rating, and therefore both the 45 A and 32 A appliances are sized based on the appliance rather than a habit of each appliance’s required usage rating; thus, neither number is considered a “standard” rating for a particular appliance, instead, both numbers are listed as standard accessory rating due to the fact that they are both in accordance with the latest wiring regulations. For (the most popular) cooker units found in domestic kitchens, the capacity is generally 45 A regardless of what load they are controlling because that is what the majority of supply companies manufacture, and for the price difference it’s not worth it to manufacturers to provide larger circuit breakers that will have a limited number of applications. — This is due to the use of 45 A circuit breakers across many regional installations.

The decision about what size to install is made within the circuit itself. A full-size cooker or dual oven will draw sufficient current that it should be supplied through a dedicated radial circuit wired in 6 mm² cable protected at either a 32 A or 40 A rating. A compact oven or small hob, typically rated below approximately 7.2 kW’s, may be operated off a 32 A circuit. The type of cable and circuit breaker to be used will depend on the rating of the appliance and method of installation. Accessories connected to the circuit should be matched or rated equal to or greater than the circuit current (e.g., cable, isolator).

For hobs rated greater than 7 kW and that are considered induction systems, the start-up current and not simply the running current is essential. Class C and Class D circuit breakers are selected to avoid the nuisance tripping that can occur when using these appliances. The choice of circuit breaker should only be considered in connection with circuit accessories, as all components (i.e. appliance, cable and isolator) should be selected as a system.

The Diversity Calculation That Decides the Breaker

The Diversity Calculation That Decides the Breaker

When a 14 kW cooker is calculated, it has a nameplate current of approximately 60.9 A, if operated at a voltage of 230 V. This suggests a 63 A circuit would be appropriate. The reason for this is that not every component is operated at full rating or power together at once, so therefore we must use the method provided by BS 7671 Appendix 15.

The formula to calculate the maximum demand on a circuit is: the first 10 A of the total load current, 30% of the remaining current, and 5 A for the socket if one is provided within the control panel. For example, with a full load of 14 kW, this would be calculated as follows: 10 A + 30% of the remaining 50.9 A (30% of 50.9 = 25.3 A) + 5 A (for the socket); so, therefore we have: 10 A + 25.3 A + 5 A = 30.3 A of total maximum demand on this circuit; so the circuit would need to be protected by a 32 A breaker and installed using 6 mm² cable.

The following table (Table 1) provides a clear illustration of the difference between the nameplate rating and the diversified ratings of certain types of cooking appliances. As you can see in Table 1, the values provided in the second and third columns are not representative of the nameplate current for each individual cooking appliance. The figures shown are derived from BS 7671.

Appareil Nameplate current at 230 V Diversified, no socket Diversified, with socket Typical circuit
Single oven, 3 kW 13 A 10.9 A 15.9 A 16 A or 20 A radial, 2.5 mm²
Oven plus small hob, 7.2 kW 31.3 A 16.4 A 21.4 A 32 A radial, 6 mm²
Cooker, 10 kW 43.5 A 20.0 A 25.0 A 32 A radial, 6 mm²
Range cooker, 14 kW 60.9 A 25.3 A 30.3 A 32 A radial, 6 mm²
Range cooker, 20 kW 87.0 A 33.1 A 38.1 A 40 A radial, 10 mm²

This is why a radial circuit of between 6 mm² and 10 mm² will suffice when wiring a commercial kitchen appliance. However, this has nothing to do with whether the nameplate rating of the appliance will be satisfied by the maximum demand calculated via BS 7671. Additionally, the 5 A load for the socket on the control panel may not actually need to be taken into account as a load for the final distribution circuit or final subdistribution circuit, which is why there is a risk of being over-protected in some instances if this is not done correctly.

This is also why the final maximum demand calculation for a cooking appliance will differ between a 14 kW rated cooker and a cooker rated at 20 kW.

These calculations provide guidance to those installing or upgrading their cooking appliances, as they will show you that it is perfectly acceptable to operate a 14 kW range cooker from a 32 A rated circuit, something which would normally come as a shock to many potential customers who have seen only the nameplates on these cooking appliances. Also, it has been explained previously that if a control unit has a socket located within the control unit, then this will be added to the maximum demand because in most cases this will also provide a means for using other appliances at the same time, just like other auxiliary devices connected to a control panel may also provide a load on a final distribution circuit.

Finally, the number specified in this instance is an indicator for designing a circuit to safely supply and operate an appliance. This number alone does not imply that additional circuits can now be created to supply and operate additional appliances. Whenever a second oven has been added to an existing circuit in a kitchen, the calculation of load must be redone rather than simply adjusted, or based on previously done calculations.

Types: With Socket, With Flex Outlet, Vertical and When Each Fits

45 A DP switch with a 13 A socket. Isolates, and provides an outlet at countertop height. However, it is not recommended to use directly above the cooking surface/high-hat, or to have more than one appliance connected on the same circuit with this combination of devices; therefore, it is most appropriate for kitchens that do not have enough circuit outlets.

45 A DP switch without a socket. Isolates, but provides only a clean plate. More typically used when the switch is located close enough to another circuit outlet to allow the use of the second circuit outlet.

45 A DP switch with a flex outlet. Provides isolation as well as allows the appliance to have a flex outlet readily available at the plate. Most frequently used in situations where an appliance tail reaches a wall and the tail can be run in a flex outlet from the appliance to the wall. The disadvantage of using a flex outlet at the kitchen wall face is aesthetically unpleasing.

Vertical or tower unit. This product works the same as other 45 A DP switches, but it has a lower profile due to its vertical configuration. It is commonly used where there is not enough space to accommodate a standard type DP switch near the wall and a tall unit has been placed next to the wall. There is also a significant cost savings associated with this type of switch.

32 A input. An isolating switch for small appliances (oven or hob) powered by a 32 A circuit. This type of switch is frequently used in conjunction with other products manufactured using a modular construction technique (2 x 3″, etc.). It uses two modules to provide a “compact” appliance solution.

This type of product allows an individual or project to purchase a switch and socket as separate components and assemble them into one frame. The modular system allows projects to “standardise” on one wiring accessory range and have the flexibility to add appliances at a later stage. However, it should be noted that the total cost of purchasing both a switch and socket combined in a modular frame is generally higher than purchasing either device separately. It is more expensive per position and it addresses the actual need that if a developer chooses one accessory range then for every cooker position the same frame, plate finish and depth of boxes can be used and prevent a second product family being used to produce the cooker position. This is the way that the modular plate and module range are designed.

Finishes and Materials: What Survives a Kitchen

There is a total of four finishes available on the market and the choice is going to be based on cleaning rather than how they look.

The least expensive and enough for easy cleaning with no fingerprints showing at all, is white moulded plastic. Brushed stainless steel looks good in a contemporary style kitchen and leaves water marks due to sitting close to a hob. Polished chrome shows everything and only gets selected due to its design, rather than being practical. The preferred choices of design currently are matte black and black nickel, which are the worst for grease because their surfaces scatter light, rather than reflecting it.

The materials behind the finishes count more than the actual finishes. A moulded plate consists of one piece of thermoplastic with metal inserts for fixing. It does not corrode in humid kitchens. A metal plate consists of pressed or cast metal on top of a plastic carrier, and the area between the plastic and metal is where corrosion will begin. Having a separate earth terminal bonded to the metal of the plate in addition to relying on screws to fix the plate to the wall will provide better protection than only relying on screws for securing the plate.

For either a rental building or a spec build, using a unit made with white moulded materials will provide the best solution in terms of cost-effectiveness, durability, etc. If a client’s remodelling project involves choosing a finish, the plates should match the other accessories within that particular room and therefore the timing of ordering a cooker with the rest of that client’s order is critical. The combinations of switch-socket systems offered for sale are grouped by their respective plate systems, which is why it’s important to order kitchen accessories at the same time as they will be used in conjunction. This will prevent situations where plates ordered two months apart will not match the rest of the room.

What the Socket on the Unit Can and Cannot Do

What the Socket on the Unit Can and Cannot Do

An outlet socket on the cooktop is a 13 A conception à trois broches carrées de 13 ampères et 230 volts. Elle comprend un interrupteur à bascule intégré et des volets à ressort qui bloquent l'accès aux fentes sous tension et neutre à moins que la broche de terre plus longue ne soit insérée en premier. La tension et le type de fiche sont fixés par la norme nationale ; le choix pour l'acheteur se situe dans la finition, l'intégration USB et la fonctionnalité intelligente. GOG Electric fabrique des dispositifs de câblage pour les normes NEMA nord-américaines et BS 1363 britanniques, avec les bonnes tensions et intensités pour chaque marché. outlet; it is a separate fused device that is powered from the same cooking supply as that supplied to the cooktop. It may be used for kettle, mixer, and charger functions, making it a valuable asset to kitchen designs that otherwise have limited wall outlets. The mechanism used in the manufacture of 13 A sockets present on cooktop units operates using the same mechanics as typical wall socket devices, which provides an identical operational feel when using the outlet on a cooktop compared with a wall socket unit.

A cooktop socket cannot function as a standard utility socket for use with appliances that have high loads; the limiting factor for it operating in this capacity is the 13 A fuse limit, which limits the socket to a maximum output of approximately 3 kW. Furthermore, the total load on the circuit to which the cooktop socket is connected will include the cooktop itself. Diversity calculations did not include the load of a second oven plugged into the outlet.

Guidance on positions has changed, and the accepted practice in the past was to mount a socket above the worktop on the control unit directly above the hob. The new guidance discourages mounting a socket above a hob, as the risk of fire is increased when an electrical extension leads across a heated surface and steam and grease can easily reach the socket. When the plate must be above the hob, the type without the socket is the safest option, with the socket installed separately to the side.

One guideline from the trade is repeated: if the oven is a gas cooker, it is advised that the socket not be located on the same control unit, as the electrical isolation and the gas isolation should not rely on the same plate being accessible. Though this is a guideline and not a regulation, it is precisely the type of detail that an inspector will take into account.

Position, Clearance and the 2 m Rule

The control unit must be easily accessible to the person using it in case of emergency isolation. The accepted location of the control unit should be around 2 m from the appliance based on the route a person would take to reach the appliance, rather than the shortest distance between the appliance and the control unit through a cabinet.

The height is a design preference, rather than a hard and fast rule. The normal placement of the worktop is approximately 1,000 mm to 1,100 mm from the floor to the centre of the worktop, as this allows for ample accessibility without bending and is visible without needing to look behind appliances. In theory, it is acceptable to place a unit behind a drawer at 300 mm above the floor, whereas in practice, no one would use a drawer that high.

The placement of the unit in relation to the hob is the area where controversy over placement comes in. The heat, grease and steam are all present directly over the hob and the cable runs through the hottest part of the wall behind it. It is now standard practice to place the unit on the side 300 mm from the edges of the hob and also out of the splash zone.

In addition to the previous point, clearance from the appliance location is also important. When using a freestanding stove, you will have to pull it out for servicing, and the unit that is located directly behind it will be in the path of the stove every time it is moved. Instead, the unit should be placed on the wall next to the stove or above the countertop, not behind a short wall of space.

Wiring: The Six Terminals and the Order of Connection

As mentioned previously, the control unit has six terminals in two groups: Supply In, Load Out and Socket Feed. In the switch section, there is L In, N In, L Out, N Out and a shared earth terminal; in the socket section, there are also L, N and E coming from the load side through a 13 A fuse.

The connection order is: Supply First, Load Second, Socket Third, so that you can test each stage individually prior to adding the next. Connection of the incoming live wire to pin ‘L’, the incoming neutral wire to pin ‘N’ and the earth wire to the earth terminal. Connection of the outgoing live wire to pin ‘L’ and the outgoing neutral wire to pin ‘N’, and if the earth terminal is not a double terminal then connect it to the same terminal as the outgoing live and neutral wires. The socket is fed from the load side.

Two points need to be made as these are where the faults are found. The earth terminal on a metal plate must be bonded to the plate not just to the earth wire, and the conductor must be sleeved. Also a 6 mm² conductor in a 45 A connection requires a specific stripping length of usually 12 to 15 mm; too short the insulation sits under the screw and too long there is bare copper outside the terminal.

Regulations: BS 7671, Part P and What an Inspector Checks

The BS 7671 Part P regulations guide an inspector on how to check for compliance.

The requirements for the switch and cooker control units have been identified in the BS EN 60669 standard and the BS 4177 standard, which means that a buyer can purchase a product rated at 45 A and have the installation checked against the standard reference rather than assessed by a product label.

Four checks are made; whether the circuit is dedicated and not connected to another ring final circuit, if the size of the cable connected matches the breaker and the method of installation, and that isolation is double pole and accessible. In England and Wales, any new cooker circuit added to a kitchen is notifiable under Part P, and as such, any work done on the circuit will need to be certified.

The RCD (Residual Current Device) requirement is the fourth point that could affect an older installation. For example, a socket outlet that’s expected to supply an appliance that would typically be used outside will require 30 mA of RCD protection as per BS 7671. In addition, a cooker circuit that has a socket which takes 13 A of supply is also considered as having a socket. This means that a socket on a cooker circuit will usually require RCD protection.

Therefore, it is most likely that you will have to install a circuit breaker for any socketed cooking circuits that you may have, as these will either be supplied by a consumer unit with an RCBO circuit breaker or by a consumer unit with a split circuit with RCD protection. Therefore you should ensure that you know before you purchase your cooker circuit; the type of consumer unit that you will be using.

Marques et Gammes de Prix

Gamme Price, 45 A DP with socket Typical brands Ce que vous obtenez
Trade white £10 to £18 BG, Click, generic trade ranges Moulded plate, neon indicator, basic terminals
Branded white £18 to £30 MK, Crabtree, Hager, Schneider Get Better terminals, consistent plate colour
Metal finish £25 to £60 MK, Crabtree, Click, Hamilton Brushed steel, chrome or black nickel plate
Modular or designer £60 and up Designer ranges, modular systems Separate modules in one frame, matching series

There are many factors that can cause the price of an item within a band to change — the biggest factor is the finishing of the item because whether the plate is metal or plastic will determine the cost of that item (e.g. a metal plate will be more expensive than a plastic one). Therefore, you must ensure that you are comfortable paying the price for the brand and finish you wish to install. The terminal design is the most expensive of all three and it is worth paying for if it is on a 6 mm² conductor because a bad terminal on a large diameter cable is where the joint is going to heat up.

The difference between the cheapest product and the most expensive product is only about £50, which is less than the cost of 1 hour of labour for an electrician. The installation of a new cooker circuit is not the best item to optimise on a kitchen refit, so it is easier to narrow the range of products you want to use by looking at a comparison of UK electrical supply products.

Méthodes d'installation et coûts associés

Three different methods of installing a new cooker exist and each has a different installation cost compared to the actual price of the product being installed.

The most economical method to replace an existing appliance appertaining to the electric cooker circuit (hereinafter “old-style”) is a like-for-like replacement. The installation would involve isolating the existing cooker, disconnecting the old cooker, reconnecting a new cooker and testing to ensure it meets the required specification. An electrician will usually spend between 30 to 45 minutes completing this job. The only material needed to complete the installation of a new cooker will be the cooker plate itself. This method can also be done by anyone competent to carry out DIY tasks.

The installation method of adding an additional socket to an existing cooker circuit (i.e. an “old-style”) circuit would still be considered a “like-for-like” replacement installation, provided the plate that you are replacing does not currently have a socket installed. If the circuit is generally suitable to be completed in this manner, the process would be the same as that described in the previous paragraph; however, because the circuit now has an outlet, the safety requirements of RCD protection and “diversity” must be taken into account. These additional items relate to an engineering review of the installation and, therefore, a diversity allowance of 5 amp must be taken into account when adding a new socket to an existing old-style appliance.

If you require the installation of a new cooker circuit (i.e. not replacing an existing old-style circuit), this will require the purchase of a complete new cable run from the consumer unit through to the new cooker, the installation of a new breaker, and the installation of a new cooker plate with a connection unit attached to the appliance (this includes all wiring and other components, which are included as part of the overall cost of installing the new cooker circuit). Between two and four hours of electrician time, plus cable will be chargeable under Part P, and the cost of the material is only a small portion of the total. When rewiring the kitchen, the entire cooker circuit is included in the installation with the same cost as everything else, and the extra expense of adding a new circuit is minimal compared to the cost of cabling through the kitchen that would otherwise be runnable from the original cooker circuit. In other cases, the cost to run a cable from the existing circuit and to add a new cooker is utilised when there is an existing circuit that has never had a cooker’s circuit added to it, which is why we often see new cookers on existing cooker circuits.

Faults, Replacement and When to Stop

Faults, Replacement and When to Stop

There are four clear symptoms of failure with an accessory, as opposed to an appliance:

If the accessory has been damaged due to a loose terminal connection, the plate will be warm to the touch and/or if the switch stinks like melting plastic, this is usually indicative of being loose and/or the normal operating limits of the switch have been exceeded.

Should the accessory’s normal operation not be restored after checking the connection at the terminal, and the neon remains illuminated when the switch is switched off, then either the switch is configured as a single pole or the wiring is incorrectly installed.

If the mechanism within the switch does not positively click into the ON position, the switch’s mechanism may be worn down, and if the switch was rated at 45 A, the fault is a safety concern rather than a nuisance, which creates an even greater concern.

If there is a heat mark at the terminal, then this would be seen as a stop signal. It indicates a sustained overheating of the cable and therefore the cable may need to be cut back rather than fully re-terminated.

Most replacements are usually like-for-like or equivalent types; because they are usually like-for-like replacements, many customers opt to replace the accessory instead of having the accessory repaired because the mechanism is not repairable or serviceable once a replacement is received. The circuit cannot be changed; a new faceplate for an undersized appliance is only fixing an aesthetic issue on an equipment design flaw.

If your project will be purchasing for multiple homes, the accessory you choose must come from a series that will be produced in five years, because if you replace a faceplate that does not match the other accessories in the kitchen it will be a small but obvious oversight. This is why we recommend that you purchase all the kitchen’s accessories from the same series, and that our complete range of sockets and switches is formulated so that faceplate systems and module sizes are the same throughout your project.

FAQ

How do I wire a cooker switch and socket?

Connect the incoming supply to L in, N in, and then the earth to the earth terminal; connect the outgoing load to L out and N out; connect the socket feed from the load side via its 13 A fuse. Always test with a voltage tester before working on a circuit and use the correct strip length for your 6 mm² conductors. Ensure that the earth terminal is connected to a metal plate and not just relying on the screws securing the plate to the wall.

Can I add a socket to my cooker circuit?

Yes, if the circuit is rated appropriately. When replacing a switch-only version of a cooker control unit with a socket version, although in several respects a like-for-like swap, the local circuit design must allow for the changes to occur. For example, when conducting a diversity calculation in accordance with BS 7671 Appendix 15, 5 A is added for the presence of a socket outlet on the control unit; therefore, the circuit now has an additional socket outlet, which necessitates a 30 mA RCD protection.

What type of switch do you require for your cooker?

A cooker requires a double-pole switch (a device that can isolate both the live and neutral supply) rated at least the same rating as the circuit current; this means that, in practice, the appliance will require a 45 A cooker control unit. The double-pole operation is significant because, when a circuit breaker is a 32 A, it is acceptable to use a double-pole 45 A mechanism; however, on a 32 A circuit, a 20 A switch is not acceptable.

What are the current regulations regarding cooker switch installations?

According to BS 7671, the isolator must be located so that it is easily accessible from the cooker, usually around 2 m away. As per the Part P regulations in England and Wales, all new cooker circuits must be notified to the local authority of the building/household. Where a cooker circuit has a socket outlet, the circuit must have an RCD of 30 mA. The double-pole operation and the 45 A rating are accessory specifications rather than circuit specifications.

Références

Conclusion

To correctly install a cooker isolator with a socket outlet, it is crucial to use a 45 A double-pole isolator and a fused 13 A socket outlet. The circuit size is determined by a diversity calculation based on the appliance nameplate, which is the reason that a 14 kW range cooker can be operated on a 32 A circuit breaker; and, as a rule of thumb, the isolator should be located within 2 m of the appliance (ideally easily accessible but not directly over the cooktop). The socket outlet offers extra convenience, but it also adds 5 A to the design current and makes the installation subject to the RCD requirement; therefore, the socket version is not automatically the better choice.