How to Wire an Outlet in Series

How to Wire an Outlet in Series

Most individuals unfamiliar with wiring outlets will describe the outlet as being wired in series because the series word describes a wiring process, but that description is not accurate either. Understanding the difference between “outlet” and “series” before cutting the wire will save hours of work later.

Quick answer: the hot, neutral and ground wires run from outlet to outlet in a branch circuit, and each of the three wires serves the same function at all three outlets. True series wiring would have each outlet on the same electrical connection path. The practical way to wire an outlet in series is to use a daisy chain wiring technique with a pigtail connector. The neutral wire must be pigtail wired, which keeps its continuity constant regardless of whether the devices connected to it are powered on. All outlets have their wires connected to each other at the same place, and the electrical flow comes from the same source at the same voltage, but each outlet splits its own current into different devices or loads.

Outlets Are Wired in Parallel, Not Series

When an outlet is wired in parallel, each outlet receives 100 percent of the voltage supply from the utility company; therefore, all three outlets will receive the same voltage supply to power multiple light bulbs, kettles or other devices off the same circuit. Each outlet’s electrical current flow is only increased by the combined current flow of all loads connected to the circuit.

When an outlet is wired in series, the electrical current flow source will pass through each device, and each device will use a portion of the total voltage, resulting in a lower supply voltage; therefore, if there are two outlets wired together in series on a 120 volt AC circuit, each outlet would see approximately 60 volts, and if a third outlet were added, its voltage would be even lower. Because of this configuration, many devices with motors, appliances with on-off switches, and switch mode power supplies will not work properly, and if one outlet is unplugged, all the downstream outlets will have their paths severed.

What “In Series” Means to an Electrician

The proper way an electrician will describe the wiring of a junction box where the outlets are heavily interconnected is a daisy chain configuration, with multiple cables linked together at the junction box and a single wire as the power feed to all the outlets from the utility. When you see the term “daisy chain”, you should think of the wiring of outlets as being parallel but physically connected to one another.

In the industry, two different words are used to describe the same topology: daisy chain wiring. As a result, there is no confusion when referring to a multiple outlet configuration. Daisy chain wiring is the same as in-series wiring, and it refers to the order of the outlets, the physical layout, and not to the electrical topology or wiring configuration.

The last outlet is commonly called the ending outlet, and it is where the other outlets have their power source terminated. Because it is at the end of the line and is connected to the first outlet upstream, the last outlet will be the first to lose power if the connection fails somewhere upstream.

This means that if there is a fault at the first outlet in an outlet chain, all outlets will lose power; however, if the last outlet has a fault, only the last outlet will lose power.

The practical difference between an outlet on a run and an outlet on a spur is important to understand. A spur is a branch circuit that breaks away from a circuit at a junction box or from a device and thereby terminates. Therefore, if there is a fault on the spur, it will affect only the spur; however, if there is a fault in the middle of a run, then the run will be broken into two runs.

Most residential circuits are runs; therefore, the confusion that occurs when trying to locate a fault is due to not knowing where the run finished.

Why a True Series Connection Would Fail

Why a True Series Connection Would Fail

The reason a true series connection would not work comes down to three things, and each of them explains a rule that appears later in the article.

The voltage is divided equally amongst all the loads in the series circuit; therefore, if there are two identical loads in series, each device receives 1/2 of the voltage supplied from the source. Therefore, if you connected a 120V outlet to a pair of 60V devices, the light from the lamp would be very dim, and so forth. As soon as you added another load to that same series of devices, the problem would only get worse! This is why you could buy a string of electric light bulbs that would operate off of one wall outlet as late as 100 years ago but cannot today.

The other reason a series circuit would not work is because in a series circuit there is only one current path for all of the devices in the circuit. Thus, the current rating of the smallest device in series limits all other devices; if there is a break in the series current path, then it will stop the entire series of connected devices. In other words, that is the opposite of how a branch circuit was designed to function.

The Neutral is Dangerous. In your series circuit the neutral should be considered a combined path and not as the return for each individual device. If you were to isolate one device then the other devices in the circuit could be left in a live condition that could potentially cause harm. Therefore the National Electric Code (NEC) requires that the neutral connections be pigtailed together instead of looped through a device.

Before You Start: Tools, Material and the Circuit Check

The tools required are few. Primarily you need a voltage tester (to confirm live voltage on a known good circuit), a complete screwdriver set including a torque screwdriver, wire-strippers, side cutters, cable knife, level and drill with appropriate size bit for mounting boxes or securing plasterboard. A non-contact tester is helpful for the initial check but cannot confirm that the device is dead.

The types of materials required depend on the circuits to which you will be connecting devices. In the US the circuit is a 15 A circuit and as such you will use 14 AWG two-conductor cable with ground and receptacles, boxes, and connectors for the 15 A circuit. For a 20 A circuit you will use 12 AWG two-conductor cable with ground, and receptacles, boxes and connectors rated for the 20 A circuit. In the UK you will typically use 2.5 mm² twin and earth for either a 32 A ring or 20 A radial circuit and BS 1363 outlets. In both cases the ratings of the devices must match the rating of the circuit, so a 20 A receptacle on a 15 A circuit is a mismatch (not an upgrade).

Lastly, the circuit check should be completed before any devices are disconnected. A breaker has to be identified and switched off, then use a volt/ohm tester to check for power at the outlet the breaker feeds, as the last step before work begins. It is also important to mark the circuit breaker so that no one can accidentally turn it back on during your work. In addition, a circuit that is not being energized by a switch is still considered “live” as long as it is powered through a different circuit breaker, so it will need to be isolated properly with the proper tools.

The decision of what device to use will be made separately from how to wire it. Just as there are several different types of switches and outlets that can be purchased for use with the same electrical plate, there are several different types of plates that can be used for each of these devices or outlets. However, the different types must all come from the same series, because the depth of the outlet and the type of plate must match, and mixing series is not a shortcut.

Planning the Run: Load, Box Fill and Cable Length

To plan the electrical run properly, one must take into account the load, the fill of the box and the length of the wire.

The viability of the run is determined by three limits, all of which are less expensive to check on paper than to check inside of a wall.

The first limit is the electrical load. A 15 A, 120 V circuit is 1,800 W, and the continuous load is 80 percent of that, or 1,440 watts. This means that a workshop run with a heater will not be able to draw the maximum continuous load because the heater will need a dedicated circuit as soon as the continuous load approaches the maximum. The total number of outlets for a twenty ampere circuit can be calculated the same way as above, where the total number of outlets is not the deciding factor; however, the connected load is the determining factor.

The second limit is to evaluate the fill of the box. The volume allowance includes every conductor, device, and connector; therefore, having a box too small for the quantity of conductors enclosed is a code violation no matter how tidy the conductor’s placement is. For example, if a single-gang box contains two wires, a receptacle, and a pigtail, it is near the maximum capacity. The addition of a third conductor will require either a deeper box or the installation of a two-gang box.

The third issue with cable length relates to voltage drop rather than safety. The voltage drop at full load to a long run is significant for a 120V circuit, and the solution is either using larger cables or making the run shorter; installing newer or better outlets will not fix the problem.

Removing the Old Device

First, ensure that you have verified the circuit is not powered. Next, remove the screws that hold the outlet in place and pull the outlet out by using the metal yoke. It is recommended that you take a photograph of how everything is wired before any wires are disconnected so you will have an exact record of what goes where; this will help you to determine which cable is connected to the source and which cable is continuing to the next outlet.

After you have removed the screws, disconnect the cable from the outlet. Keep the two cables separated while you check them; if the two cables go into the same box, then one of the cables is the source and the other is the continuation; and only testing with power on, or tracing back to the previous outlet, will confirm which cable is the source.

When you have opened the box, take the opportunity to inspect the inside of the box. Check for damage to insulation, missing ground wires, any damage to conductors due to improper stripping and any signs of overheating at the terminals. A burnt brown neutral will have become overheated and will need to be cut back rather than being re-terminated as is.

The Two Ways to Connect the Next Outlet

There are two acceptable methods and one unacceptable method for connecting a new outlet.

Through-terminal wiring involves connecting both supply (feed) conductors to one set of terminals on the new receptacle and connecting the downstream continuation wiring to the other set of terminals of the new receptacle. Most outlets have two screws located on each side of their body to attach wires to. The outlet will carry the downstream load through its internal connections, therefore this is a very quick way to connect wires, but is only permitted for hot wires on many different types of devices. It basically places the entire downstream load of the circuit onto the receptacle’s internal wiring.

Pigtails involve connecting a short wire to each leg of the outlet using a suitable method and connecting the pigtail to the existing device. The outlet only carries its own load, and the pigtail is joined with an appropriate connector for both wires. Under the current code, this should be your preferred way of connecting neutrals, because the code states that the continuity of grounded conductors cannot be interrupted because the device is removed.

One method that is unacceptable is terminating at one screw and continuing on a second screw, or otherwise known as “double tap” connection. Inspectors describe the defect as two conductors under one terminal screw. The reason for this defect is that when a conductor is inserted under a terminal screw and the strands heat up, the connection will fail.

When connecting conductors to terminals, the strip lengths are specified by the manufacturer. The strip length for a screw terminal will generally be between 12 mm and 15 mm, whereas for a back-wire clamp they use a strip gauge. If the conductor’s strip length is too short, it will not have a good electrical connection, and if it is too long, it will expose bare copper outside of the terminal, which is a grounding short circuit that needs to be covered.

two approved ways to Connect the Next Outlet

Grounding: The Connection That Gets Skipped

Grounding is commonly overlooked when making connections between three devices, and therefore should be completed last. All connection methods (metal to metal, metal to plastic, and plastic to plastic) must be made at all three points to complete the grounding process.

In a metallic box, the ground will bond both the metal box and the electrical device. Each box is typically equipped with either a ground screw or a self-grounding receptacle (listed). There is nothing to connect the ground to the plastic box, so there is no way to attach the ground to either the box or the outlet. Since there is no way to bond a plastic box to an electrical system, it is also not possible to terminate the ground in the plastic box, which means the ground will continue to terminate at the next outlet in the circuit.

When you must splice a ground at some point in the run of conductors, it is important to use a connector that has been approved by a testing lab and to ensure that the pigtail used to connect two conductors is short enough that you can fold the pigtail back into the box without putting any strain on the connection point. A twisted and taped ground is not an approved method of splicing and should be treated as a “failed” joint when it is pulled out of the box twenty years after installation.

Closing the Box and Restoring Power

After you’ve finished installing the electrical device, fold back the conductors in a zig zag pattern until they fit properly into the metal box. The ground must always be placed first when folding over wires and devices, as the weight of the device could compress the joints of the connections against the back of the box.

Align the receptacle with the square base of the box using a level after you tighten the terminal screws to the proper torque as indicated on the label of each device (approximately between 1.7 and 2.3 Nm). If you tighten the terminals by “feel,” they will either be too loose or too tight, and both can generate heat. To restore power after an outage, follow the steps in reverse order: First confirm that no connections are touching each other. Next confirm that the correct plate is on the panel before restoring the breaker to its original position. Finally, turn on power and test for power coming from the outlet instead of going to the panel. If the breaker trips again immediately, there is a fault in the new cable, and the power must be removed before the fault is investigated.

When adding an additional outlet to an existing circuit, you will follow the same sequence of steps but work backward from the outlet to the circuit.

Testing: The Five Checks Before the Tools Go Away

Check Instrument Expected result What a failure means
Voltage hot to neutral Multimeter or tester Mains voltage, 120 V or 230 V No supply, or a broken hot
Voltage hot to ground Multimeter Same as hot to neutral Open ground
Voltage neutral to ground Multimeter Close to zero Neutral and ground reversed or shared
Polarity Socket tester Correct on all lamps Hot and neutral reversed
Downstream outlets Tester at each All live Continuation cable not connected

IMPORTANT: If you tested a GFCI-protected circuit using the test button on the GFCI device and it tripped, you can reset it. If you do not have a GFCI-protected circuit, you will not be able to test it with a plug-in tester with a GFCI button, so please take the time to verify the operation of the GFCI device.

Finally, you should perform the last check no one thinks to perform — lightly tug on each conductor at its terminal connection. A conductor that moves with light tension is loose and can heat when current flows. It takes approximately ten seconds for each outlet to catch a fault that would otherwise go undetected with a voltage test.

Common Mistakes

Mistake Consequence Correct approach
Two conductors under one terminal Loose joint, arcing, heat Pigtail with a listed connector
Neutral looped through the device Downstream outlets dead when the device is removed Pigtail the neutral
Supply and continuation swapped Outlet works, rest of run does not Test with the circuit live before disconnecting
Ground not continued to the next outlet Downstream outlets ungrounded Splice and continue the ground
Receptacle rating above the circuit Device rated for current the cable cannot carry Match device to circuit, not to preference
Box too small for the conductors Damaged insulation, code violation Calculate fill, use a deeper or two-gang box

Based on that table, most wire failures occur when an outlet box is treated as a junction box rather than as a device that belongs on a circuit. In this case, an outlet is a connection point; it is not designed to be a junction and should not contain joints. Rather than connecting conductors under the outlet’s screw, plug the conductors into a connector; and it becomes easier to keep the outlet and everything associated with it to a consistent standard when they are among the same manufacturer, as is the case with all types of plates, modules, and sockets manufactured for that line of products.

Common Outlet Wiring Mistakes

When to Stop and Call an Electrician

Four conditions signal that a contractor should stop and not continue.

The first condition involves an aluminum branch conductor. Aluminum does not hold up to the screw pressure and needs to be terminated in a different way. Only receptacles that are rated for CO/ALR (copper-aluminum receptacles) or listed pigtails are acceptable solutions. A circuit that has all its wires and connections but does not have ground, will typically require the installation of new cable rather than the installation of a new device to provide a ground connection. A circuit with no spare capacity in the panel and adding an additional outlet will require the installation of a new circuit. Any signs of damaged wiring at the panel rather than damaged wiring at the outlet indicate an issue upstream of the work that has been done.

All of these issues can be fixed by a qualified professional electrician; however, the cost of fixing the issues incorrectly is quite high. The decision to determine if a circuit run is a like-for-like replacement or a new circuit will be made at the service panel location and not at the wall location.

FAQ

Can electrical outlets be wired together in series?

Legally and electrically incorrect, it is possible; however, the two outlets would share the voltage and load. If you removed the first outlet, it would disconnect the whole series. Instead, a daisy chain of the cables is used as a parallel connection.

How do you wire multiple outlets in series?

To connect outlets with cabling to create a continuous circuit and protect against any potential faults that could result in a permanent open circuit, connect to the supply pair and continuation pair at each outlet by connecting to two separate terminal sets or by pigtailing the two together so that all devices carry only their own loads (pigtailing is to be done for every neutral connection). Additionally, the ground wire must be continued to be connected through every outlet box. When installing each outlet in an existing circuit, test the outlet as each outlet box is completed rather than testing all outlets at the end of the circuit.

Do you wire up outlets in series or parallel?

Outlets must be wired in a parallel configuration (i.e., daisy-chained, not series configuration), since parallel configuration provides full voltage at each outlet and allows each outlet to withdraw the current it requires; therefore, if one device fails in a parallel configuration, the other devices will still function normally. Wiring in a series configuration offers no benefits to branch circuits and offers several different failure modes.

What is the maximum number of outlets I may tie to a single wire?

Code does not specify a certain number of general-purpose branch circuits for the maximum number of outlets that may be tied, but rather sets an upper limit based on the continuous load of connected devices (a maximum load of 1,440 Watt on a 15 Amperes 120 Volt circuit under the 80 percent continuous load rule) and therefore the practical range for tieing outlets onto a 15 Ampere circuit would be approximately 8–10 total outlets and 10–13 total outlets on a 20 Ampere circuit, and any larger single nominal fixed appliance above the nominal wattage of approximately 1,000 Watts must be wired to a separate dedicated branch circuit.

References

Conclusion

The distinction between wiring in series and parallel for the purpose of creating a daisy-chain circuit is important because the method determines how much voltage will be supplied to the devices, and failsafe devices, which fail to supply voltage to all outlets, do so due to a fault in the circuit. The only methods of wiring at a work site are to connect via through-terminals and pigtails, with the only exception being the ground wire, which must be connected via a pigtail.

Every other component of an outlet installation is discipline-based. Always use a tester to verify that a circuit is completely dead after the circuit has been tested and confirmed to be live, document the existing circuit termination’s configuration before disconnecting the original terminations, identify the supply and continuation pairs, connect all ground wires continue to all boxes, torque each terminal connection, and verify the integrity of each conductor connection prior to installing the cover plate. The five electrical tests will identify failures that the tug test will not detect, while the tug test will detect failures that the five tests cannot.

 